2024/1/23
■Product Introduction(13385606475)
LC series oval gear flowmeter is the main products of our company. LC oval gear flowmeter is one of the typical displacement meter, used for measurement of pipeline fluid flow under certain pressure. It has a simple structure, reliable use and high accuracy, flow field has no special requirements for import and export of the pipe, the viscosity of the measured medium range and the characteristics of the flow range is very wide. And therefore is widely used in petroleum, chemical industry, medicine, transportation, food and other industrial and commercial sector of liquid flow detection. Lc series oval gear flowmeter is particularly suited to the measurement of oil fuel.
In order to meet market and customer demands, HeFei Walrus Instrument company, combined with 10 years manufacturing experience, continuous improvement and innovation, introduced in different environmental conditions are suitable for the use of elliptical gear flowmeter products. , Light-weight oval gear flowmeter, high-temperature type oval gear flowmeter , high-viscosity oval gear flowmeter, electronic displayoval gear flowmeterand etc.
■Working principle
In the measuring chamber, a part of oval wheels and cover plate make a fan shape cavity which is used as a measuring element. The oval wheels are rotated by the little pressure difference in the inlet and outlet of the meter and drive the inlet liquid through the cavity to the outlet, each revolution of the oval wheels displaces fluid four times the volume of cavity, the total revolutions of the oval wheels and revolutions rate will be transferred to the counter.
■Product standards and production license
⑴ The professional standards of the People's Republic of China:JB/T2942-1999《General technical conditions the liquid volume flowmeter》
⑵ Enterprise standard《Liquid volume flowmeter》Q/JD2.004-2010
⑶ Connecting flange standards:JB/T79~82-1994 GB/T9112-2000 JISK And other flange standards required by customers.
■ Oval gear flowmeter technical parameters
●The major component material and the nominal pressure
Model |
shell、Front cover、back cover |
cover board |
Oval gear |
axle |
axle sleeve |
Nominal diameter(MPa) |
LC-TE4020LW.13/N40D |
cast steel |
cast iron |
aluminum alloy |
stainless steel |
Oil bronze or rolling bearings |
1.6 MPa |
●Technical index
⑴ The level of accuracy: 0.5grade
⑵ The nominal pressure: 1.6 MPa
⑶working temperature:0~+150℃
⑷Measured liquid viscosity:8~400 mpa.s
⑸Starting flow rate:0.2m³/h
⑹Flow range :0.3~6.0m³/h
⑺MAX flow rate:7.2m³/h
■ Installation dimension
Output signal:NO
Flow Direction(Select):
① Left ←→ Right
② Lower←→ Upper
Instrument height: A= 70mm
B= 150mm
Flange to flange length:240mm
Conn. Size: GB2506 40A
Flange Spec.:
OD=150mm,
PCD=110mm,
n-Ø=4-Ø18(M16)
■Flowmeter piping method
⑴A filter should be installed in front of the meter, and be sure that the arrow on the casting of the meter and filter pointing the same direction of the liquid flow.
⑵Whether the pipe line is vertically or horizontally installed, the wheel’s shaft of the meter must be fixed horizontal, that is ,the dial is vertical ti the surface.
⑶Pipes to the installation of the meter, the pipe must be throughly cleaned.
⑷While the meter is installed properly, the counter may be turned 180° or 90° for easy reading.
⑸A regulating valve must be fixed at the of the meter, a shutoff valve at the outlet, the valve must be slowly opened to prevent from a sudden impact, and water hammer.
⑹It is forbidden to clean the meter with steam.
⑺For the continuous operating department, a bypass should be mounted.
⑻The filter should be cleaned out of impurity to prevent from blocking, the meter should be tested and overhauled in a fixed period.